RE: Definitive supported snapvault doc
I do not see it in that document. I think the NOW site knows what I said about it and is punishing me. -----Original Message----- From: Jordan Slinge
View Articlequestion about quotas for 7mode DFM 4.x
7 mode; 8.2 something.. User wants to create a user that has rights to manager Quotas.. What rights do they need? Also, in the custom alerting, can w
View ArticleRe: Definitive supported snapvault doc
Hi Jeremy, First of all a quick note: 7-Mode and Clustered ONTAP are completely different in this regard. 7-Mode SV is based upon _Qtree_ SnapMirror
View ArticleRE: Definitive supported snapvault doc
See TR4183 http://www.netapp.com/in/media/tr-4183.pdf --- With best regards Andrey Borzenkov Senior system engineer FTS MBG MOM EAI RU FOS [cid:ima
View ArticleRe: Definitive supported snapvault doc
So is snapvaulting from an 8.1 7 Mode box to a 7.3x filer officially supported (assuming QSM)? *Jeremy Page*|Senior Technical Architect|*Gilbarco Ve
View ArticleRe: Definitive supported snapvault doc
I just double-checked and don't see a reason why not... On 11/22/2013 1:36 PM, Jeremy Page wrote: > So is snapvaulting from an 8.1 7 Mode box to a 7.
View ArticleOnCommand 5.2 7 mode question on quotas and custom messaging
Not sure this went out, so I am going to send again. Is it possible to not only alert the user if they are over quota, but to also CC the storage ad
View ArticleConsistency Point Type M
Good morning, does anyone know what consistency point type M is and what's causing it? I was getting them yesterday on one of my 3240s, 8.1.3P1, it h
View ArticleRe: Consistency Point Type M
Hi Alexander, hmmmm. Only ISCSI. Lot's of writing, hardly reading. Did you try (or evaluate) setting '*minra on*' on the volumes that are active? A
View ArticleAW: Consistency Point Type M
Hi Sebastian, well, in this particular case, the client was doing some heavy database restore operations, so it was mostly write. I guess "minra" sta
View ArticleRe: Consistency Point Type M
Type 'M' is caused by low mbufs, seems you may be getting low on memory, and the f or v seems to indicate you're flushing to disk, possibly due to low
View ArticleRe: Consistency Point Type M
So I see, that this was not the typical workload... I suggested minra, because it solved a similar problem at one of my students company (I'm a NetA
View ArticleRe: [OT] General Purpose Storage Discussion
Taken me entirely too long, but the 'General Purpose Storage Discussion' mailing list is now live. Its a mailman list, so subscribe as you did for t
View ArticleRe: Consistency Point Type M
Hello All: Hey wait, unless you are using something lower than 7.3X, minra isn't likely to do much for you. NetApp changed and added in many new mem
View ArticleRe: Consistency Point Type M
+1 on not touching minra after 8.0. At this point it's a deprecated option that no longer does good, and can do (not too much, but measurable perfor
View ArticleAW: Consistency Point Type M
Hi all, thanks for your valuable insights and suggestions. I've read several times now that the 3240s with Flash Cache or the 3240s itself are very l
View ArticleRe: Consistency Point Type M
Not sure there is anything to 'blame'. Its just an earlier CP event than via timer or volume. If you had M's with B's, ya..bottleneck. On Mon, Dec
View ArticleAW: Consistency Point Type M
Well, actually I was seeing high CPU usage and degraded performance, so this type of workload must have triggered a bottleneck somewhere... Alexand
View ArticleRe: AW: Consistency Point Type M
Sure. Had to be it. Sent from my iPhone > On Dec 3, 2013, at 10:57 AM, Alexander Griesser <ag@anexia.at> wrote: > > Well, actually I was seeing
View ArticleFlexCache monitoring
Hi, Is anybody on this list using FlexCache for NFS access over WAN? What kind of performance metrics would you be tracking to detect potential per
View Article