RE: SVM DR in 8.3.1
Future releases will have improvements. That's all I can say in this forum. :) From: Gelb, Scott [mailto:scott@redeight.com] Sent: Monday, July 06, 2
View ArticleR: cDOT and Oracle
Hi Justin, excellent advices and starting points. Thanks! Da: Parisi, Justin [mailto:Justin.Parisi@netapp.com] Inviato: lunedì 6 luglio 2015 16:00
View ArticleR: SVM DR in 8.3.1
Again, interesting for it summarize the two official docs. We've just created a test and it seems to work: unfortunately up to now we don't have yet t
View ArticleRE: SVM DR in 8.3.1
You can always run the destination in the "Identity discard" mode to avoid IP clashes. That should allow you to test. I've added the SVM DR TME to th
View ArticleR: SVM DR in 8.3.1
We need identity true. a lot of cifs configuration are not brought if false. Think to vfiler Dr of 7mode... Bye - Sent by mobile - -------- Me
View Articlealerting for faulty disks
Hi, Last week I happened to notice a disk which was "disabled due to excessive phy changes". I contacted Netapp support and they promptly sent a repl
View ArticleRE: NVRAM6 Card Installed in the Wrong Slot
In HA pair usable NVRAM size is reduced in half (second half is used to mirror partner NVRAM). Whether or not it will have visible impact depends on y
View ArticleRe: formatting output from 8.3 CLI statistics commands?
If there was a feature request, mandatory 'don't reformat output' options on all the commands would be one. Having hit similar problems, I've ended u
View ArticleRE: FAS2xxx Upgrade - Flash Cache Performance Estimation?
Hi Toasters Sorry it's taken so long to get reply back... I've been distracted with other "fires" for the last week. A big thank you to Michael, And
View ArticleRe: FAS2xxx Upgrade - Flash Cache Performance Estimation?
Steve - Regarding the 2020 I'd replace that guy, especially to save money on maintenance renewals if you're coming up on them. You could probably ge
View ArticleRe: NVRAM6 Card Installed in the Wrong Slot
3140 should be more than adequate for that workload, especially with that number of spindles (15K disks should be able to handle 250 IOPS each) -- giv
View ArticleRE: NVRAM6 Card Installed in the Wrong Slot
Thanks Tony, Thanks Andrei, I was only asked to pass a quick eye over the system to spot any obvious issues. I ran Config Advisor and it came back c
View ArticleRE: NVRAM6 Card Installed in the Wrong Slot
Note that moving NVRAM means shutting down filer and this alone may clear any temporary resource shortage. -----Original Message----- From: Stephen
View ArticleRe: NVRAM6 Card Installed in the Wrong Slot
IF I recall... Placing the NVRAM card in the "HA" slot will halve the NVRAM and establish a baseline for the system to think it is part of an HA pair
View ArticleRE: formatting output from 8.3 CLI statistics commands?
Thanks all for several good suggestions along the lines of setting the session arguments to change the output, I hadn't gone that way. Note that it d
View ArticleRe: Another SSD question
Tony Bar wrote: > 'wafl awa' can help you determine the impact > adding cache of either kind will have on writes/reads and how much > optimally you
View Article8.3, NDMP and CommVault
Hello All, Forgive me asking what are essentially newbie questions but as we're setting up our first 8.3 clusters I pretty much am new. We have a pr
View ArticleRe: 8.3, NDMP and CommVault
Here's a document I found from Commvault that explains how to enable cluster aware backups on the Netapp: http://docs.commvault.com/commvault/v10/arti
View ArticleRE: NVRAM6 Card Installed in the Wrong Slot
Thanks Tim Unfortunately, this is an old system that was upgraded and no longer under support. However, your tip led me to dig through the HA Config
View ArticleRE: NVRAM6 Card Installed in the Wrong Slot
There is another command we sometimes need to run from the loader or cfe prompt to remove the environment variable for the partner. Otherwise the con
View Article